Venture “Vietnam”, Banking

May-3rd-2010

Client: Venture “Vietnam”, DegelisDégelis, Témiscouata
Project Manager: Mccarty Millie
Project Started: Mar 16, 2007
Total SCADA Sensors: 2786
Active SCADA Sensors: 1404
Manageable SCADA snsrs: 1465

Networking:

  • Switchboard Catalyst 3560 48 10/100/1000T + 4 SFP Enhanced Image
  • Gateway screen PIX 515E-UR Bundle (Chas, Unrestricted SW, 128MB, 2 FE, VAC +)
  • Routing and pass my drug test system code 194350
  • Router 2801 Voice Bundle, PVDM2-8, SP Serv, 64F/256D
  • iMG646BD-ON Active Ethernet Outdoor intelligent Multiservice Gateway.

    100BX WAN (100M Single BiDi Fiber), 6 x 10/100 TX LAN, 4 x FXS. Requires enclosure EN646. Order with RG005G and RG013 cable for power and battery backup.
  • CM202/1 Media Blade 10/100TX to 100FX, 15Km Singlemode (dual fibre) with 802.3ah support

Servers:

  • 490427-421 Proliant DL160R06 E5504 NHP (Rack1U XeonQC 2.0Ghz (4Mb)/2×2GbUD/SATA RAID (1+0/1/0)/160GbSATA HDD (up to 4)/noDVD/2xGigEth)
  • 412140-B21 HP BladeSystem cClass c7000/3000 Active Cool 200 Fan Option Kit (incl 1 active fan)
  • 470065-300 Proliant DL380R06 E5520 (Rack2U XeonQC 2.26Ghz (8Mb)/3×2GbRD/P410i (256Mb/RAID5+0/5/1+0/1/0)/1×300Gb15kHDD (6)) LFF/noDVD/iLO2std/4xGigEth/1xRPS460)
  • 470065-174 Proliant ML370T06 E5520 (Tow XeonQC 2.26 GHz (8Mb)/3×2GbRD/P410iwBBWC (512/RAID5+0/5/1+0/1/0)/2×146Gb10k (8/24up) SFF/DVDRW/iLO2std/4xGEth/5xFan/1xRPS750)

Power Systems:

  • SYH4K6RMI APC Symmetra RM 4KVA/2.8kW Expandable to 6KVA/4.2kW or N+2, Rack mount, in: 1PH, out: (8) С13, (2) С19, Pre-Inst. Web/SNMP, 8U
  • SYA16K16IXR APC Symmetra LX 16kVA/11.2kW Scalable to 16kVA/11.2kW N+1 Ext. Run Tower, 220/230/240V or 380/400/415V, input: 1PH/3PH, output: 1PH, Pre-Inst. Web/SNMP
  • SUVTP15KH4B4S APC Smart-UPS VT 15KVA/12kW 400V w/4 Batt Mod Exp to 4, Int Maint Bypass, Parallel Capable, w/Start-Up Servise
  • SURTD3000RMXLI APC Smart-UPS RT RM, 3000VA/2100W, On-Line, Extended-run, Rack 3U (Tower convertible), with PowerChute Business Edition sofware, Black
  • ACF402 Rack Air Removal Unit 100-240V 50/60HZ for NetShelter SX 750 mm Enclosure

Printing:

  • Canon iR5880C, 58ppm, A3, a paper
  • Canon iR5075, 75ppm, A3, a paper

Desktop Software:

  • Office Pro 2007 Win32 Russian CD
  • The licence for use of the program of the control of the certificated version of OS Windows Server 2003 Standard Edition (SrvS_Check)
  • The licence for use of the program of the control of certificated version OPK Office 2003 Professional (Office_Check)

System Software:

  • MSRT100 Executive SCADA system on 100 external points of input-output.
  • IMR-2,5K Industrial MasterReport (IMR) – cервер the press of the technological data on 2500 external points of data gathering from OPC and SQL sources
  • External HDA-clients (SCADA and MES systems, databases) can download all archives of the project. Corresponds to version OPC HDA 1.1
  • Without restriction of number of the connected drivers

Data Protection:

  • B2PCIPANLJ, PANDA Cloud Internet Protection – Analyze Module> 5001 licences (2 years), 467,3988
  • B1UCEPCPB, Transition with Panda Cloud Office Protection on Panda Cloud Protection 11 – 25 licences (1 year), 781,66
  • B3CEPC, Panda Cloud Email Protection 26 – 50 licences (3 years), 2902,8384
  • B3GDIAS? M, GateDefender Integra Anti-spam Module 101 – 1000 licences (3 years), 761,5377
Related