Client: Trading company “Detachment”, Terrebonne, Les Moulins
Project Manager: Rutledge Julio
Project Started: Dec 27, 2009
Total SCADA Sensors: 2700
Active SCADA Sensors: 1971
Manageable SCADA snsrs: 1973
Networking:
- Router 2811 Security Bundle, Adv Security, 64F/256D
- The module 1-Port RJ-48 Multiflex Trunk – E1 VWIC2-1MFT-T1/E1 =
- Routing and pass drug test system code 209268
- DES-7210 Layer 3 Switch Base Unit Chassis with Back Plate and 2 Empty Slots for CPU modules and 8 Empty Slots for line cards 1 Power Supp
- The module 2-Port 2nd Gen Multiflex Trunk Voice/WAN Int.
Card – T1/E1 - Router 2801 Router/AC PWR, 2FE, 4slots (2HWICs), 2AIMS, IP BASE, 64F/128D
- Switchboard Catalyst 2960 48 10/100 Ports + 2 1000BT LAN Base Image, including a cord of food CAB-ACE
Servers:
- 466131-421 Proliant ML150T06 E5502 NHP SATA (Tower XeonDC 1.86Ghz (4Mb)/1×2GbUD/SATA RAID (1/0/1+0)/160GbSATA (max 4NHP LFFHDD)/DVD/GigEth)
- 507778-B21 ProLiant BL460 G6 Xeon X5550 QC (Xeon 2.66GHz/8Mb/3×2GbRD/RAID P410i (ZM) 1,0/no SFF HDD (2)/2xFlex1/10Gb MF/iLO blade edit/1slot in Encl)
- 470065-303 Proliant ML350T06 E5506 LFF (Tower XeonQC 2.13GHz (4Mb)/2×2GbRD/P410i (ZM/RAID1+0/1/0)/1×300Gb15kHDD (6LFF/8up)/DVDRW/iLO2std/2xGE/1xRPS460)
- 504055-421 ProLiant ML330T6 E5504 NHP SATA (Tower XeonQC 2.0GHz (4Mb)/1×2GbRD/SATA RAID (1/0/1+0)/250Gb nhp SATA (max 4NHP LFFHDD)/DVD/iLO2std/2xGigEth)
- 490454-421 Proliant DL160R06 E5520 HP SATA/SAS (Rack1U XeonQC 2.26Ghz (8Mb)/3×2GbUD/P410 (ZM/RAID1+0/1/0)/noLFF HDD (2 (4w/bckpln))/noDVD/2xGigEth)
- 210-27055-005 PE R610 E01S Xeon E5520×1/6GB (3×2) GB/80GB SATA//PERC6i/iDRAC6 Enterprise/NoOS/1 non-red PSU 717W/3yNBD
Power Systems:
- SURT10000RMXLI APC Smart-UPS RT RM, 10000VA/8000W, On-Line, 1:1 or 3:1, Rack 6U (Tower convertible), Extended-run, Pre-Inst. AP9619, with PC Business, Black
- SURT10000RMXLI APC Smart-UPS RT RM, 10000VA/8000W, On-Line, 1:1 or 3:1, Rack 6U (Tower convertible), Extended-run, Pre-Inst. AP9619, with PC Business, Black
- SYH6K6RMI APC Symmetra RM 6KVA/4.2kW Expandable to 6KVA/4.2kW or N+1, Rack mount, in: 1PH, out: (8) С13, (2) С19, Pre-Inst. Web/SNMP, 8U
- SURT10000RMXLI APC Smart-UPS RT RM, 10000VA/8000W, On-Line, 1:1 or 3:1, Rack 6U (Tower convertible), Extended-run, Pre-Inst. AP9619, with PC Business, Black
- AR3350 NetShelter SX 42U 750mm x 1200mm Enclosure
Printing:
- Phaser 7760DX too, as DN + a paper feeder bol.emk. 2500 sheets (obshch.emk.lotkov 3150л) + ON PhaserMatch 4.0.
Desktop Software:
- Full package for the certificated version of OS Windows Server 2008 Datacenter for use on 1 automated workplace
- Windows Vista Ultimate SP1 64-bit Russian 1pk DSP OEI DVD, the right of use
- The licence for use of the program of the control of the certificated version of personal computer Office 2007 Standard (Office 2007S_Check)
System Software:
- Inet-5 Viewing of reports in Internet clients (Internet Explorer) – to 5 simultaneously connected clients.
- PID – expert Station of engineering support SAR without restrictions of number of variables
- IMS-1K Industrial MasterServer (IMS) – a server of gathering of the technological data on 1000 arhiviruemyh parametres and 1000 external points of input-output.
- MSRT-InterBase-SQL The Module of communication with SQL-server InterBase
- MSRT-Psp Process equipment Certification
Data Protection:
- B2CEPA, Panda Cloud Email Protection 1 – 10 licences (2 years), 2419,032
- B1PCIPBACI, PANDA Cloud Internet Protection – Browser Access Control Module 3001 – 5000 licences (1 year), 148,9752
- B2UCEPCPE, Transition with Panda Cloud Office Protection on Panda Cloud Protection 101 – 250 licences (2 years), 987,36