Client: Subsidiary company “Anniversary”, Fossambault-sur-le-Lac, La Jacques-Cartier
Project Manager: Tran Laurence
Project Started: Mar 29, 2010
Total SCADA Sensors: 1981
Active SCADA Sensors: 1672
Manageable SCADA snsrs: 1747
Networking:
- Switchboard Catalyst 3750 48 10/100/1000T + 4 SFP Standard Mul
- iMG664A ADSL2/2 + Multiservice Gateway with Analog and Digital VoIP.
1 x Annex A, ADSL2 +, 4 x 10/100TX, 2 x FXS, 1 x ISDN BRI - Routing and how to pass a piss test system code 238723
- The module of digital processing of a voice (12-Channel Packet Voice/Fax DSP Module)
- Router Cisco3745,120-phone CCME, 30-chan digital DSP, 64F/256D
- The module of digital processing of a voice (12-Channel Packet Voice/Fax DSP Module)
Servers:
- 491332-421 Proliant DL380R06 E5540 (Rack2U XeonQC 2.53Ghz (8Mb)/3×2GbRD/P410i (256Mb/RAID5+0/5/1+0/1/0)/noHDD (8 (16up)) SFF/noDVD/iLO2std/4xGigEth/1xRPS460)
- 490454-421 Proliant DL160R06 E5520 HP SATA/SAS (Rack1U XeonQC 2.26Ghz (8Mb)/3×2GbUD/P410 (ZM/RAID1+0/1/0)/noLFF HDD (2 (4w/bckpln))/noDVD/2xGigEth)
- AZ197A Proliant DL160R06 L5520 Pluggable SATA HPM (Rack1U 2xXeonQC 2.26Ghz (8Mb)/2×2GbUD/SATA RAID (1+0/1/0)/noLFF HDD (4))/noDVD/2xGigEth)
- 465475-421 Proliant DL120R05 E2160 NHP (Rack1U P1.8Ghz DC (1Mb)/1×1Gb/SATA RAID (1/0)/160GbSATA HDD (up to 2)/noCD.noFDD/GigEth)
Power Systems:
- SUVTP20KH2B2S APC Smart-UPS VT 20KVA/16kW 400V w/2 Batt Mod Exp to 2, Int Maint Bypass, Parallel Capable, w/Start-Up Servise
- AR3157 NetShelter SX 48U 750mm x 1070mm Enclosure with Sides Black
- SYPM10K16H Symmetra PX Power Module, 10/16kW, 400V
- SYRMXR4B4I APC Symmetra RM 4U Rack-mount Ext. Run Frame w/4 SYBT2’s
- NBWL0500 NetBotz 500 Wall Appliance with Camera
Printing:
- Canon iR5055N, 55ppm, A3, a paper
Desktop Software:
- The licence for use of the program of the control of certificated version OPK Office 2003 Professional (Office_Check)
- WinPro 7 RUS Upgrd OLP NL, the right of use
- Acronis Backup and Recovery 10 Workstation incl. AAP el. Licence 50 – 99 Copies
System Software:
- MSRT100-Red Redundant network executive SCADA-system on 100 external points of input-output (on 2 computers).
- MSRT-TE Library kontrolov for use SCADA in ASUTP and SAR heat power objects (nearby 20 FB and VFB)
- MSRT-HDA-Client The Client for reception of archives from OPC HDA servers and their record in archives MasterSCADA and external SQL servers (in the presence of the module of communication with a server).
Data Protection:
- RB1GDICC? S, GateDefender Integra a full configuration (prolongation) 26 – 100 licences (1 year), 2589,22818
- B3PCIPPRF, Panda Cloud Internet Protection (Premium Bundle) 200 – 500 licences (3 years), 4988,4912
- B3GDIAM? T, GateDefender Integra Anti-malware Module> 1001 licences (3 years), 533,07639
- B1CEPB, Panda Cloud Email Protection 11 – 25 licences (1 year), 1532,0536