Client: Stock company “Pestered”, Berthierville, D’Autray
Project Manager: Wallace Gary
Project Started: Dec 18, 2006
Total SCADA Sensors: 2717
Active SCADA Sensors: 1958
Manageable SCADA snsrs: 1998
Networking:
- МаршрутизаторCisco Small Business 107 ADSL Broadband Router
- Modular router Cisco 3725 c 2-mja ports 10/100 with ON IP
- Routing and first-aid kits system code 241082
- CM202/2 Media Blade 10/100TX to 100FX (SC), 40km Single-mode, with 802.3ah Support
- Router 2801 bundle, HWIC-1ADSL, SP Svcs, 64F/192DR
- Modular router Cisco 3725 c 2-mja ports 10/100 with ON IP
Servers:
- 444809-421 ProLiant ML110G5 E2160 NHP SATA (Tower P1.8GHzDualCore1Mb/1×512MB/160GB nhp SATA (up to 4)/6-port SATA RAID (0,1,1+0)/DVD, noFDD/GigEth)
- 470065-122 Proliant ML150T06 E5504 NHP SATA (Tower XeonQC 2.0Ghz (4Mb)/1×2GbUD/SATA RAID (1/0/1+0)/250GbSATA (max 4NHP LFFHDD)/DVDRW/GigEth) repl 466131-421
- 491324-421 Proliant DL380R06 E5530 (Rack2U XeonQC 2.4Ghz (8Mb)/3×2GbRD/P410i (256Mb/RAID5+0/5/1+0/1/0)/noHDD (8 (16up)) SFF/noDVD/iLO2std/4xGigEth/1xRPS460)
- 506667-421 ProLiant ML110G6 X3430 NHP SATA (Tower XeonQC2.4GHz (8Mb)/1×2GBUD/250GB nhp SATA (up to 4)/6-port SATA RAID (0/1/10)/DVD/GigEth/iLO100i std)
- AZ198A Proliant DL160R06 L5520 Pluggable SATA HPM (Rack1U 2xXeonQC 2.26Ghz (8Mb)/2×2GbRD/SATA RAID (1+0/1/0)/noLFF HDD (4))/noDVD/2xGigEth)
- 487928-421 Proliant ML350T06 E5530 SFF HPM (Tower 2xXeonQC 2.4GHz (8Mb)/6×2GbRD/P410iwBBWC (512Mb/RAID5/5+0/1+0/1/0)/noHDD (8SFF/16up)/DVD/iLO2st/2xGigEth/2xRPS750)
Power Systems:
- AR3157 NetShelter SX 48U 750mm x 1070mm Enclosure with Sides Black
- SBP120KHC1M1 Service Bypass Panel for 1×120 KW UPS
- SYAXR9B9I APC Symmetra LX Extended Run Tower w/9 SYBT5, 230V
- SYPM2KU APC Symmetra RM 2KVA/1.4kW Power Module
- SURTD5000XLI APC Smart-UPS RT, 5000VA/3500W, On-Line, Extended-run, Black, Tower (Rack 3U convertible), Pre-Inst.
Web/SNMP, with PC Business - SYA8K16RMI APC Symmetra LX 8kVA/5.6kW Scalable to 16kVA/11.2kW, N+1 Rack-mount, 220/230/240V or 380/400/415V, inp. 1PH/3PH, outp: 1PH, (8) C13, (10) C19, Pre-Inst.
Printing:
- Phaser 6360DT sngl.net the laser printer f. А4 (40/40 it tsv/is black-is white. Str/mines, memory 256Mb,
Desktop Software:
- Base package for the certificated version of OS Windows XP Professional for use on 1 automated workplace
- Get Genuine Kit WinXP Pro SP2 Russian DSP 1 License OEI CD, the adjusting complete set
- The licence for use of certificated version UserGate Proxy and Firewall 5.2.F to 15 sessions
- The licence for use of the program of the control of the certificated version of OS Windows Windows Vista Business 64-bit (Vista Business 64-bit_Check)
System Software:
- MSRT1K-Net Network executive SCADA-system on 1000 external points of input-output
- MAS-U MasterSCADA Arcive Server (MAS) – the allocated archival SCADA-server on unlimited quantity arhiviruemyh parametres and external points of input-output.
- MSRT500-Red Redundant network executive SCADA-system on 500 external points of input-output (on 2 computers).
- Inet-10 The Generator of reports with possibility of viewing of reports in Internet clients (Internet Explorer) – to 10 simultaneously connected clients.
- MSRT-View Executive system – the network client without management functions. For work on a client place less, than from 500 points, it is recommended to take MSRT500-Net
- MSRT-Inet5 The Server on 5 simultaneously connected clients
Data Protection:
- B2PCIPDLPJ, PANDA Cloud Internet Protection – Data Leakage Prevention Module> 5001 licences (2 years), 467,3988
- B2GDP9DLWF, Panda GateDefender Performa 9000 – the Device of protection of network Web-filter Module for GateDefender Performa 9500 (Lite) (2 years), 174487,5
- B1RGDP9DPAM, Panda GateDefender Performa 9000 – the Device of protection of network Anti-malware Module for GateDefender Performa 9500 (Large) – prolongation (1 year), 427680