Client: Society “Camouflage”, Mont-Laurier, Antoine-Labelle
Project Manager: Parks Ester
Project Started: May 18, 2009
Total SCADA Sensors: 2319
Active SCADA Sensors: 1400
Manageable SCADA snsrs: 1449
Networking:
- Router 2811 with WIC-1ADSL (ADSLoPOTs), SP Ser IOS, 64F/256D
- Switchboard Catalyst 3750 24 10/100/1000T PoE + 4 SFP Standard Image
- Routing and osha first aid kits 25 employees system code 153681
- iMG664WB ADSL2/2 + Multiservice Gateway with Analog and Digital VoIP.
1 x Annex B, ADSL2 +, 4 x 10/100TX, 802.11b/g, 2 x FXS, 1 x ISDN BRI - Switchboard Catalyst 3750 12 SFP Enhanced Multilayer Image
- Router 3825 w/AC PWR, 2GE, 1SFP, 2NME, 4HWIC, IP Base, 64F/256D
- CM202/2 Media Blade 10/100TX to 100FX (SC), 40km Single-mode, with 802.3ah Support
Servers:
- 470065-168 Proliant ML310T05p X3220 hot plug SATA/SAS RPS (Tower X2,4GHzQuadCore/8Mb/2×1Gb/P212 (ZM/RAID1+0/1/0)/2×500GbSATALFFHDD (4)/DVD/2xGigEth/iLO2Std/2xRPS)
- 507780-B21 ProLiant BL460 G6 Xeon E5530 QC (Xeon 2.4GHz/8Mb/3×2GbRD/RAID P410i (ZM) 1,0/no SFF HDD (2)/2xFlex1/10Gb MF/iLO blade edit/1slot in Encl)
- 470065-300 Proliant DL380R06 E5520 (Rack2U XeonQC 2.26Ghz (8Mb)/3×2GbRD/P410i (256Mb/RAID5+0/5/1+0/1/0)/1×300Gb15kHDD (6)) LFF/noDVD/iLO2std/4xGigEth/1xRPS460)
- PE R710 E02S Xeon E5530×1/6GB (3×2) GB/73GB SAS 10K/PERC6i/iDRAC6 Enterprise/NoOS/1 non-red PSU 870W/3yNBD
- 507783-B21 ProLiant BL460 G6 Xeon E5506 QC (Xeon 2.13GHz/4Mb/3×2GbRD/RAID P410i (ZM) 1,0/no SFF HDD (2)/2xFlex1/10Gb MF/iLO blade edit/1slot in Encl)
- 487507-421 Proliant DL180R06 E5540 HP SATA/SAS HPM (Rack2U 2xXeonQC 2.53Ghz (8Mb)/6×2GbRD/P212 (256Mb/RAID5+0/5/1+0/1/0)/noHDD LFF (12)/noDVD/2xGigEth/1xRPS750W)
Power Systems:
- SURT6000RMXLI APC Smart-UPS RT RM, 6000VA/4200W, On-Line, Extended-run, Rack 3U (Tower convertible), Pre-Installed Web/SNMP, with PC Business, Black
- SYA8K16RMI APC Symmetra LX 8kVA/5.6kW Scalable to 16kVA/11.2kW, N+1 Rack-mount, 220/230/240V or 380/400/415V, inp. 1PH/3PH, outp: 1PH, (8) C13, (10) C19, Pre-Inst.
- AR3300 NetShelter SX 42U 600mm x 1200mm Enclosure
- SYA12K16IXR APC Symmetra LX 12kVA\8.4kW scalable to 16kVA\11.2kW N+1 Ext. Run Tower, 220/230/240V or 380/400/415V, inp.1PH/3PH, outp: 1PH, Pre-Inst. Web/SNMP
Printing:
- Phaser 5500DT net.laz.printer – too (5500DN) + a feeder on 1000ะป.
Desktop Software:
- The licence for use of the program of the control of the certificated version of OS Windows XP Professional (XP_ Check 3.0)
- GGK-Win Vista Business SP1 Russian Legalization DSP ORT OEI DVD, the right of use
- FrFrntTMGStd 2010 RUS OLP NL 1Proc
- SQLSvrStd 2008 RUS DiskKit MVL DVD
System Software:
- The electronic documentation a part of a package is not adapted for listing
- Report-Inet-5 The Generator of reports with possibility of viewing of reports in Internet clients (Internet Explorer) – to 5 simultaneously connected clients.
- OPC-server (HDA) for access to archives Master SCADA. External HDA-clients (SCADA and MES systems, databases) can download all archives of the project. Corresponds to version OPC HDA 1.1
- External HDA-clients (SCADA and MES systems, databases) can download all archives of the project. Corresponds to version OPC HDA 1.1
- MSRT-MC-Email The Conclusion of messages to an E-mail
- MSRT-HDA-Client The Client for reception of archives from OPC HDA servers and their record in archives MasterSCADA and external SQL servers (in the presence of the module of communication with a server). Is a part MAS.
Data Protection:
- Total Protection Module (to 500 users) (3 years), 445500
- B3PSMT, Panda Security for Sendmail> 1001 licences (3 years), 178,97546205
- B1CPD, Panda Cloud Protection 51 – 100 licences (1 year), 1625,03
- UJ36AP10, Panda Antivirus Pro 2010 – Upgrade – on 3 personal computers – (a subscription to 3 years), 2822,688