Group “Trail”, Farming

Dec-24th-2009

Client: Group “Trail”, Valcourt, Le Val-Saint-François
Project Manager: Hess Martina
Project Started: Apr 12, 2005
Total SCADA Sensors: 1264
Active SCADA Sensors: 509
Manageable SCADA snsrs: 563

Networking:

  • Router Cisco SOHO 78 G.SHDSL router
  • iBG915FX Business Gateway, 5 x Ethernet ports, 8 x FXS ports, 100M SFP WAN
  • Routing and detox drug test system code 392919
  • Switchboard Cat4500 E-Series chassis 6-Slot Chassis, fan, no ps
  • The switchboard 2955 12 TX w/MM Uplinks

Servers:

  • AM439A Proliant DL785R6 8431 (7U 4xOptSC 2.4Ghz (6Mb)/8×4Gb6400/no SFFHDD (8/16up)/RAID P400iwBBWC (512Mb)/2xGigEth MF/DVDcombo/iLO2std/3xRPS)
  • 470065-300 Proliant DL380R06 E5520 (Rack2U XeonQC 2.26Ghz (8Mb)/3×2GbRD/P410i (256Mb/RAID5+0/5/1+0/1/0)/1×300Gb15kHDD (6)) LFF/noDVD/iLO2std/4xGigEth/1xRPS460)
  • 594869-421 Proliant ML350T06 E5620 SFF (Tower XeonQC 2.4GHz (12Mb)/3×2GbRD/P410i (256Mb/RAID5+0/5/1+0/1/0)/noHDD (8SFF/16up)/DVD/iLO2std/2xGigEth/1xRPS460)
  • 466482-B21 HP BladeSystem cClass 8Gb Virtual Connect Fibre Channel Module (8 external SFP slots, incl 2×8Gb LC SW SFP) req.

    VC Eth Mod in Enclosure
  • 491315-421 Proliant DL380R06 X5560 HPM (Rack2U 2xXeonQC 2.8Ghz (8Mb)/6×2GbRD/P410iwBBWC (512Mb/RAID5/5+0/1+0/1/0)/noHDD (8/16up) SFF/DVDRW/iLO2std/4xGigEth/2xRPS750)
  • 470065-168 Proliant ML310T05p X3220 hot plug SATA/SAS RPS (Tower X2,4GHzQuadCore/8Mb/2×1Gb/P212 (ZM/RAID1+0/1/0)/2×500GbSATALFFHDD (4)/DVD/2xGigEth/iLO2Std/2xRPS)

Power Systems:

  • SBPAR30K40H-WP APC Parallel Maintenance Bypass Panel, up to 3 units 30-40kVA, 400V Wallmount
  • SYA16K16IXR APC Symmetra LX 16kVA/11.2kW Scalable to 16kVA/11.2kW N+1 Ext. Run Tower, 220/230/240V or 380/400/415V, input: 1PH/3PH, output: 1PH, Pre-Inst. Web/SNMP
  • SURTD3000RMXLI APC Smart-UPS RT RM, 3000VA/2100W, On-Line, Extended-run, Rack 3U (Tower convertible), with PowerChute Business Edition sofware, Black
  • SURTD5000XLI APC Smart-UPS RT, 5000VA/3500W, On-Line, Extended-run, Black, Tower (Rack 3U convertible), Pre-Inst. Web/SNMP, with PC Business
  • SYH6K6RMI APC Symmetra RM 6KVA/4.2kW Expandable to 6KVA/4.2kW or N+1, Rack mount, in: 1PH, out: (8) С13, (2) С19, Pre-Inst. Web/SNMP, 8U

Printing:

  • Phaser 7760DN color snglodnyj the laser network printer ф.SRА3 (1200dpi, 35цв./45ч.б. P. А4/мин,

Desktop Software:

  • The licence for use of the program of the control of certificated version Microsoft Exchange Server 2007 Enterprise Edition (ExchE07_Check)
  • Base package for the certificated version of OS Windows Server 2008 Standard Edition for use on 1 automated workplace
  • The licence for use eToken Network Logon the certificated version on one workplace.

System Software:

  • MSRT100-Net (**) Network executive SCADA-system on 100 external points of input-output.
  • Drivers Modbus RTU, Dcon, etc.
  • MSRT100 Executive SCADA system on 100 external points of input-output.
  • MSRT-View Executive system – the network client without management functions. For work on a client place less, than from 500 points, it is recommended to take MSRT500-Net
  • MSRT-Mtl2 Metrological checking
  • Without restriction of number of the connected drivers

Data Protection:

  • B2PCIPADC, Panda Cloud Internet Protection (Advanced Bundle) 26 – 50 licences (2 years), 4651,3368
  • B2PCIPDLPF, PANDA Cloud Internet Protection – Data Leakage Prevention Module 200 – 500 licences (2 years), 893,8512
  • B1GDP9BTP, Transition with Panda GateDefender Performa 8050 1 device GateDefender Performa 9100
  • B3PCIPSTI, Panda Cloud Internet Protection (Standard Bundle) 3001 – 5000 licences (3 years), 1776,3768
  • RB2GDPWF? S, GateDefender Performa Web Filter Module (prolongation) 26 – 100 licences (2 years), 915,4771065
Related