Group “Neutralization”, Metallurgy

Dec-11th-2010

Client: Group “Neutralization”, Bedford, Brome-Missisquoi
Project Manager: Strickland Reynaldo
Project Started: Jul 20, 2007
Total SCADA Sensors: 1204
Active SCADA Sensors: 310
Manageable SCADA snsrs: 345

Networking:

  • The expansion module
  • Router 3845 w/AC PWR, 2GE, 1SFP, 4NME, 4HWIC, IP Base, 64F/256D
  • МодульOne-slot IP Communications Voice/Fax Network Module
  • Reserve Gateway screen PIX 535FO Bundle (Chassis, failover SW, 2 FE ports)

Servers:

  • 487795-421 Proliant ML370T06 E5520 (Tower XeonQC 2.26 GHz (8Mb)/2×2GbRD/P410i (256Mb/RAID5+0/5/1+0/1/0)/noHDD (8/24up) SFF)/DVD/iLO2std/4xGEth/3xFan/1xRPS460)
  • 466131-421 Proliant ML150T06 E5502 NHP SATA (Tower XeonDC 1.86Ghz (4Mb)/1×2GbUD/SATA RAID (1/0/1+0)/160GbSATA (max 4NHP LFFHDD)/DVD/GigEth)
  • 594869-421 Proliant ML350T06 E5620 SFF (Tower XeonQC 2.4GHz (12Mb)/3×2GbRD/P410i (256Mb/RAID5+0/5/1+0/1/0)/noHDD (8SFF/16up)/DVD/iLO2std/2xGigEth/1xRPS460)
  • 470065-154 Proliant ML150T06 E5504 Hot plug SAS/SATA (Tower XeonQC 2.0Ghz (4Mb)/1×2GbUD/P410 (ZM/RAID1+0/1/0)/1×146Gb15kLFFHDD (4/8up)/DVDRW/GigEth)

Power Systems:

  • SUVTP15KH4B4S APC Smart-UPS VT 15KVA/12kW 400V w/4 Batt Mod Exp to 4, Int Maint Bypass, Parallel Capable, w/Start-Up Servise
  • AR2901 NetShelter VL 42U 600mm x 1070mm Deep Enclosure no Sides Black
  • SUM3000RMXLI2U Smart-UPS XL, 3000VA/2850W, 230V, DB-9 RS-232, RJ-45 10/100 Base-T, USB, Extended runtimel, Rack Height 2U, Black
  • SYBT4 APC Symmetra PX Battery Module (include 4xSYBTU1-PLP)
  • SYA12K16IXR APC Symmetra LX 12kVA\8.4kW scalable to 16kVA\11.2kW N+1 Ext.

    Run Tower, 220/230/240V or 380/400/415V, inp.1PH/3PH, outp: 1PH, Pre-Inst. Web/SNMP
  • SUVTP15KH4B4S APC Smart-UPS VT 15KVA/12kW 400V w/4 Batt Mod Exp to 4, Int Maint Bypass, Parallel Capable, w/Start-Up Servise

Printing:

  • Phaser 8560DX sngl.toner.printer f. А4 (512Mb,30чт/30ё-с.ё=Ё/ьшэ,600dpi,ѕыѕё°.2400dpi, a duplex
  • Canon iR7105, 105ppm, A3, a paper

Desktop Software:

  • Windows Vista Business SP1 Russian DVD
  • Acronis Backup and Recovery 10 Advanced Server incl. AAP el. Licence 100 – 249 Copies
  • WinSvrCAL 2008 RUS OLP NL UsrCAL, the right of use
  • The licence for use of the program of the control of certificated version subd SQL Server 2005 Standard Edition (SQL Chk2005SE)
  • The licence for use of the program of safe adjustment and the control certificated ON Windows Server 2003 Enterprise Edition (SrvE_Check)

System Software:

  • MSRT2,5K-Net Network executive SCADA-system on 2500 external points of input-output
  • MSRT-X-SQL The Module of communication with a SQL-server (H – on demand of the client)
  • OPC-MSRT-HDA-Server An OPC-server (HDA) for access to archives Master SCADA

Data Protection:

  • B3GDIAM? O, GateDefender Integra Anti-malware Module 5 – 25 licences (3 years), 1087,911
  • B3PCIPANLH, PANDA Cloud Internet Protection – Analyze Module 1001 – 3000 licences (3 years), 859,4388
  • B2PCIPADA, Panda Cloud Internet Protection (Advanced Bundle) 1 – 10 licences (2 years), 4651,3368