Group “Dolynka”, Farming

Jan-9th-2010

Client: Group “Dolynka”, Kirkland, Montreal CMA
Project Manager: Vega Mathew
Project Started: Jun 17, 2006
Total SCADA Sensors: 1825
Active SCADA Sensors: 1441
Manageable SCADA snsrs: 1482

Networking:

  • Switchboard Catalyst 2960 24 10/100 + 2 1000BT LAN Base Image, including a cord of food CAB-ACE
  • Switchboard Catalyst 3750 24 10/100/1000T Standard Multilayer Image
  • Routing and personal protection blood spill kit system code 322693
  • X900-24XT 24-Port Gigabit Copper Expandable L3 + Per-Flow QoS IPv4/IPv6 Switch.

    One AC Power Supply Factory fitted. 4 Power cords (NA, EU, UK, AU) in the box.
  • X900-48FS 48-Port 100FX (SFP) Fast Ethernet L3 + Per-Flow QoS IPv4/IPv6 Switch. One AC (AT-PWR02) Power Supply Factory fitted.
  • Router 2811 w/AC PWR, 2FE, 4HWICs, 2PVDMs, 1NME, 2AIMS, IP BASE, 64F/256D
  • Module DSP on four channels a voice/fax

Servers:

  • 470065-095 Proliant DL180R06 E5504 HP SATA/SAS (Rack2U XeonQC 2.0Ghz (4Mb)/1×2GbUD/P410wBBWC (512Mb/RAID5+0/5/1+0/1/0)/160Gb LFF (4/8up)/noDVD/2xGigEth/1xRPS460W)
  • 507778-B21 ProLiant BL460 G6 Xeon X5550 QC (Xeon 2.66GHz/8Mb/3×2GbRD/RAID P410i (ZM) 1,0/no SFF HDD (2)/2xFlex1/10Gb MF/iLO blade edit/1slot in Encl)
  • 490427-421 Proliant DL160R06 E5504 NHP (Rack1U XeonQC 2.0Ghz (4Mb)/2×2GbUD/SATA RAID (1+0/1/0)/160GbSATA HDD (up to 4)/noDVD/2xGigEth)
  • 491325-421 Proliant DL380R06 E5520 (Rack2U XeonQC 2.26Ghz (8Mb)/3×2GbRD/P410i (256Mb/RAID5+0/5/1+0/1/0)/noHDD (8 (16up)) SFF/noDVD/iLO2std/4xGigEth/1xRPS460)
  • 594874-421 Proliant ML350T06 E5650 SFF HPM (Tower 2xXeon6C 2.66GHz (12Mb)/6×2GbRD/P410iwFBWC (1Gb/RAID5/5+0/1+0/1/0)/noHDD (8SFF/16up)/DVD/iLO2st/2xGigEth/2xRPS750)

Power Systems:

  • SUVTP30KH3B4S APC Smart-UPS VT 30KVA / 24kW 400V w/3 Batt Mod Exp to 4, Int Maint Bypass, Parallel Capable, w/Start-Up Servise
  • SYA16K16RMI APC Symmetra LX 16kVA Scalable to 16kVA N+1 Rack-mount, 220/230/240V or 380/400/415V, inp. 1PH/3PH, outp: 1PH, (8) C13, (10) C19, Pre-Inst. Web/SNMP
  • SYA8K16IXR APC Symmetra LX 8kVA/5.6kW Scalable to 16kVA/11.2kW, N+1 Ext. Run Tower, 220/230/240V or 380/400/415V, in: 1PH/3PH, out: 1PH, Pre-Inst. Web/SNMP
  • SYAXR9B9I APC Symmetra LX Extended Run Tower w/9 SYBT5, 230V
  • AR3100 NetShelter SX 42U 600mm x 1070mm Enclosure with Sides Black
  • SURT8000RMXLI APC Smart-UPS RT RM, 8000VA/6400W, On-Line, Extended-run, 1:1 or 3:1, Rack 6U (Tower convertible), Pre-Installed Web/SNMP, with PC Business, Black

Printing:

  • Phaser 4500DX too + (oper.pamjat 64Мб, zh.disk 20Гб, a bus a duplex, 3 л.х550л, steker 500 l, встр.Web a server, 10/100 Base-TX Ethernet)

Desktop Software:

  • The licence for use of certificated version UserGate Proxy and Firewall 5.2.F to 50 sessions
  • The licence for use of the program of the control of certificated version Microsoft Exchange Server 2007 Standard Edition (ExchS07_Check)
  • The licence for use of certificated version UserGate Proxy and Firewall 5.2.F to 50 sessions

System Software:

  • MAS1K MasterSCADA Arcive Server (MAS) – the allocated archival SCADA-server on 1000 arhiviruemyh parametres and 1000 external points of input-output.
  • MSRT2,5K Executive SCADA system on 2500 external points of input-output.
  • PID – expert – 32 Station of engineering support SAR on 32 entered variables

Data Protection:

  • B1PCMM, Panda Security for CommandLine 101 – 1000 licences (1 year), 117,96783075
  • B2PCIPANLJ, PANDA Cloud Internet Protection – Analyze Module> 5001 licences (2 years), 467,3988
  • B3GDPAS? M, GateDefender Performa Anti-spam Module 101 – 1000 licences (3 years), 1805,1264