Client: Firm “Gagra – Consulting”, SarreLa Sarre, Abitibi-Ouest
Project Manager: Porter Allison
Project Started: Jul 12, 2007
Total SCADA Sensors: 2850
Active SCADA Sensors: 1594
Manageable SCADA snsrs: 1640
Networking:
- Router 2821 w/DC PWR, 2GE, 4HWIC, 3PVDM, 1NME-X, 2AIM, IP BASE, 64F/256D
- The module 32-Channel Packet Voice/Fax DSP Module
- Routing and pass thc drug test system code 203710
- 2-Port Async/Sync Serial WAN Interface Card spare
- Switchboard Catalyst 3750 24 10/100 + 2 SFP Standart Multilayer Image
Servers:
- 490930-421 Proliant DL120R06 G6950 NHP (Rack1U 2.8Ghz DC (3Mb)/1×2GbUD/SATA RAID (0/1/10)/160Gb NHP HDD (up to 4)/noDVD/2xGigEth/iLO100i std)
- 491505-421 Proliant DL380R06 E5504 (Rack2U XeonQC 2.0Ghz (4Mb)/2×2GbRD/P410i (ZM/RAID1+0/1/0)/noHDD (8 (16up)) SFF/noDVD/iLO2std/4xGigEth/1xRPS460)
- 210-27055-004 PE R610 E01S Xeon E5530×1/6GB (3×2) GB/80GB SATA//PERC6i/iDRAC6 Enterprise/NoOS/1 non-red PSU 717W/3yNBD
- 593498-421 HP DL320 G6 L5609 4HDD SATA EU Svr
- 504056-421 Proliant ML330T06 E5506 LFF (Tower XeonQC 2.13GHz (4Mb)/2×2GbRD/P410i (ZM/RAID1+0/1/0)/noHDD (4LFF/8up)/DVD/iLO2std/2xGigEth)
- 490932-421 Proliant DL120R06 X3450 Hot plug (Rack1U 2.66Ghz QC (8Mb)/2×2GbRD/P212 (256Mb/RAID5+0/5/1+0/1/0)/no HP HDDs (up to 4)/noDVD/2xGigEth/iLO100i std)
Power Systems:
- SYA12K16IXR APC Symmetra LX 12kVA\8.4kW scalable to 16kVA\11.2kW N+1 Ext.
Run Tower, 220/230/240V or 380/400/415V, inp.1PH/3PH, outp: 1PH, Pre-Inst. Web/SNMP - SYPM Symmetra power module pack 4KVA
- SURT192RMXLBP2 APC Smart-UPS RT RM battery pack, Extended-Run, 192V bus voltage, Rack 6U, compatible with Smart-UPS RT RM 15-20kVA, Black
- SURTD5000XLI APC Smart-UPS RT, 5000VA/3500W, On-Line, Extended-run, Black, Tower (Rack 3U convertible), Pre-Inst. Web/SNMP, with PC Business
Printing:
- Canon iR5880C, 58ppm, A3, a paper
- Phaser 6360DN sngl.net the laser printer f. А4 (40/40 it tsv/is black-is white. Str/mines, memory 256Mb,
Desktop Software:
- Royalty Win Svr Std 2008 32Bit/x64 Russian 1pk DSP OEI DVD 1-4CPU 5 Clt, the right of use
- OfficePro 2003 Win32 RUS DiskKit MVL CD
- The licence for use of certificated version UserGate Proxy and Firewall 5.2.F to 150 sessions
- The licence for use of certificated version UserGate Proxy and Firewall 5.2.F to 50 sessions (updating)
- ExchgStdCAL 2010 RUS OLP NL UsrCAL, the right of use
System Software:
- IMS-1K Industrial MasterServer (IMS) – a server of gathering of the technological data on 1000 arhiviruemyh parametres and 1000 external points of input-output.
- IMR-1K Industrial MasterReport (IMR) – cервер the press of the technological data on 1000 external points of data gathering from OPC and SQL sources
- MSRT500 Executive SCADA system on 500 external points of input-output.
- MSRT-U-Net Network executive SCADA-system on unlimited number of points of points of input-output
- MSRT-InterBase-SQL The Module of communication with SQL-server InterBase
- MSRT-MasterLink-Base MasterLink – a program sluice for connection of drivers
Data Protection:
- B3GDP9DLAM, Panda GateDefender Performa 9000 – the Device of protection of network Anti-malware Module for GateDefender Performa 9500 (Lite) (3 years), 583110
- B1GDP9ETPLB, Transition with Panda GateDefender Performa 8050 1 device GateDefender Performa SB for balancing
- B1GDP9ETPLB, Transition with Panda GateDefender Performa 8050 1 device GateDefender Performa SB for balancing
- RB3GDIAS? O, GateDefender Integra Anti-spam Module (prolongation) 5 – 25 licences (3 years), 1631,8665