Firm “Chacha”, Oil and Gas

Aug-27th-2010

Client: Firm “Chacha”, Rivière-du-Loup, Rivière-du-Loup
Project Manager: White Carey
Project Started: Mar 7, 2009
Total SCADA Sensors: 1997
Active SCADA Sensors: 1399
Manageable SCADA snsrs: 1442

Networking:

  • Router 2821 w/AC PWR, 2GE, 4HWICs, 3PVDM, 1NME-X, 2AIM, IP BASE, 64F/256D
  • X900-24XT-80 24-Port Gigabit Copper Expandable L3 + Per-Flow QoS IPv4/IPv6 Switch.

    One DC Power Supply Factory fitted.
  • Routing and wedding gift basket system code 172359
  • Switchboard Catalyst 3750 48 10/100 + 4 SFP Standard Multilayer Image
  • Router 2801 V3PN bdl, AIM-VPN, PVDM2-8, FL-CCME-24, Adv IPServ, 64F/256D
  • Router 2821 V3PN bdle w/AIM-VPN,PVDM2-32,CCME-48,AdvIPServ,64F/256D
  • МодульSingle-Port 24 Channel T1 Voice/Fax Network Module

Servers:

  • 412138-B21 HP BladeSystem cClass c7000 2,25kW Power Supply Option Kit (incl IEC C20-C19 1,22m power cord)
  • AM439A Proliant DL785R6 8431 (7U 4xOptSC 2.4Ghz (6Mb)/8×4Gb6400/no SFFHDD (8/16up)/RAID P400iwBBWC (512Mb)/2xGigEth MF/DVDcombo/iLO2std/3xRPS)
  • 470065-182 Proliant ML350T06 E5506 LFF (Tower XeonQC 2.13GHz (4Mb)/2×2GbRD/P410i (ZM/RAID1+0/1/0)/1×146Gb15kHDD (6LFF/8up)/DVDRW/iLO2std/2xGE/1xRPS460)
  • 507780-B21 ProLiant BL460 G6 Xeon E5530 QC (Xeon 2.4GHz/8Mb/3×2GbRD/RAID P410i (ZM) 1,0/no SFF HDD (2)/2xFlex1/10Gb MF/iLO blade edit/1slot in Encl)

Power Systems:

  • SUA3000RMI2U Black Smart-UPS 3000VA/2700W, RackMount, 2U, Line-Interactive, USB and serial connectivity, user repl.batt, Automatic Voltage Regulation
  • AR2900 NetShelter ValueLine 42U 600mm Wide x 1070mm Deep
  • SURT10000XLI APC Smart-UPS RT, 10000VA/8000W, On-Line, 1:1 or 3:1, Tower (Rack 6U convertible), Extended-run, Pre-Inst. Web/SNMP, with PC Business, Black
  • SYPM Symmetra power module pack 4KVA
  • SYH4K6RMI APC Symmetra RM 4KVA/2.8kW Expandable to 6KVA/4.2kW or N+2, Rack mount, in: 1PH, out: (8) С13, (2) С19, Pre-Inst. Web/SNMP, 8U
  • SURTD3000RMXLI APC Smart-UPS RT RM, 3000VA/2100W, On-Line, Extended-run, Rack 3U (Tower convertible), with PowerChute Business Edition sofware, Black

Printing:

  • Phaser 6180MFP/N color the kopir-printer-scanner – a fax (А4,400МГц, 384Мб, the press 30ч.б./20цв str/mines,

Desktop Software:

  • Acronis Backup and Recovery 10 Advanced Server incl. AAP el. Licence 25 – 49 Copies
  • The licence for use of certificated version UserGate Proxy and Firewall 5.2.F to 30 sessions (updating)
  • USB-key eToken, the protected memory 64КБ, Certificate FSTEK 1883
  • Acronis Backup and Recovery 10 Advanced Server incl. AAP el. Licence 10 – 24 Copies
  • Office 2007 Win32 Russian CD

System Software:

  • MSRT100 Executive SCADA system on 100 external points of input-output.
  • MSRT-ASCUE-E Library of templates of reports under the account of the electric power for use SCADA in ASKUE and AIIS KUE, and also in technical systems of the account.
  • MSRT-U-Red Redundant network executive SCADA-system on unlimited number of external points of input-output (on 2 computers).
  • MSRT-U Executive SCADA system on unlimited number of points of input-output
  • IMS-2,5K Industrial MasterServer (IMS) – a server of gathering of the technological data on 2500 arhiviruemyh parametres and 2500 external points of input-output.

Data Protection:

  • B2PCIPURLG, PANDA Cloud Internet Protection – Dynamic URL Filtering Module 501 – 1000 licences (2 years), 556,6968
  • B2RGDP9ETP, Transition with Panda GateDefender Performa 8050 Total Protection Module (prolongation) for GateDefender Performa SB (2 years), 83813,4
  • RB3GDPAM? O, GateDefender Performa Anti-malware Module (prolongation) 5 – 25 licences (3 years), 3868,128
  • B2UCOPCPE, Transition with Panda Cloud Email Protection on Panda Cloud Protection 101 – 250 licences (2 years), 1603,008