Factory “Co-authorship Trade”, Metallurgy

Oct-2nd-2010

Client: Factory “Co-authorship Trade”, Val-d’Or, La Vallée-de-l’Or
Project Manager: Whitehead Miranda
Project Started: Jun 24, 2010
Total SCADA Sensors: 486
Active SCADA Sensors: 373
Manageable SCADA snsrs: 428

Networking:

  • Switchboard Catalyst 3750 24 10/100/1000T PoE + 4 SFP Standard Image
  • Module PVDM 8-channel 8-Channel Packet Voice/Fax DSP Module
  • Routing and best way to pass a drug test system code 252943
  • iMG664B ADSL2/2 + Multiservice Gateway with Analog and Digital VoIP.

    1 x Annex B, ADSL2 +, 4 x 10/100TX, 2 x FXS, 1 x ISDN BRI
  • The switchboard 2960 on 24 ports Gigabit Ethernet Catalyst 2960 24 10/100/1000, 4 T/SFP LAN Base Image

Servers:

  • 539843-421 Proliant DL585R6 8431 (4xOptSC 2.4Ghz (6Mb)/8×2Gb (6400)/no SFFHDD (8)/P410wBBWC (512Mb/RAID5+0/5/1+0/1/0)/2xGigEth MF/DVDcombo.noFDD/iLO2std/2xRPS)
  • 466482-B21 HP BladeSystem cClass 8Gb Virtual Connect Fibre Channel Module (8 external SFP slots, incl 2×8Gb LC SW SFP) req. VC Eth Mod in Enclosure
  • 506668-421 ProLiant ML110G6 X3450 NHP SATA (Tower XeonQC2.66GHz (8Mb)/2×2GBUD/2×250GB nhp SATA (up to 4)/6-port SATA RAID (0/1/10)/DVD/GigEth/iLO100i std)
  • 490432-421 Proliant DL160R06 L5520 NHP (Rack1U XeonQC 2.26Ghz (8Mb)/2×2GbUD/SATA RAID (1+0/1/0)/160GbSATA HDD (up to 4)/noDVD/2xGigEth)
  • 570102-421 Proliant DL385R06 2435 HPM (Rack2U 2xOptSC2.6Ghz (6Mb)/4×4Gb/P410wBBWC (512Mb/RAID5/5+0/1+0/1/0)/noHDD (8/16up) SFF/DVDRW/iLO2std/4xGigEth/2xRPS750)
  • 456972-B21 Emulex-based (LPe1205) BL cClass Dual Port Fibre Channel Adapter (8-Gb) (BL280G6,460G6,490G6,685G5,860,870)

Power Systems:

  • AR3150 NetShelter SX 42U 750mm x 1070mm Enclosure with Sides Black
  • SYPM2KU APC Symmetra RM 2KVA/1.4kW Power Module
  • SURT10000RMXLI APC Smart-UPS RT RM, 10000VA/8000W, On-Line, 1:1 or 3:1, Rack 6U (Tower convertible), Extended-run, Pre-Inst. AP9619, with PC Business, Black
  • SYRMXR4B4I APC Symmetra RM 4U Rack-mount Ext. Run Frame w/4 SYBT2’s
  • NBWL0500 NetBotz 500 Wall Appliance with Camera

Printing:

  • Canon iR5880Ci, 58ppm, A3, a paper
  • Phaser 7760GXF too, as DN + a paper feeder бол.емк.1500 sheets (obshch.emk.lotkov 2150л.) + the office

Desktop Software:

  • The licence for use of certificated version UserGate Proxy and Firewall 5.2.F to 10 sessions
  • The licence for use of certificated version SKD Device Lock
  • The licence for use of certificated version SKD Device Lock
  • The licence for use of the program of the control of the certificated version of personal computer Office 2007 Professional (Office 2007_Check)
  • ExchgEntCAL 2010 RUS OLP NL UsrCAL woSrvcs, the right of use

System Software:

  • The electronic documentation a part of a package is not adapted for listing
  • MSRT2,5K-Red Redundant network executive SCADA-system on 2500 external points of input-output (on 2 computers).
  • The vocal channel. For support GPRS or SMS – address. The number of modems – is not limited.
  • MAS-Red The Option of reservation for the allocated archival SCADA-server.
  • IMS-100 Industrial MasterServer (IMS) – a server of gathering of the technological data on 100 arhiviruemyh parametres and 100 external points of input-output.

Data Protection:

  • B3UCEPCPI, Transition with Panda Cloud Office Protection on Panda Cloud Protection> 3001 licences (3 years), 905,08968
  • B3CPF, Panda Cloud Protection 251 – 500 licences (3 years), 2867,7
  • B1PEXT, Panda Security for Exchange Servers> 1001 licences (1 year), 256,64666643
Related