Client: Cooperative “Lie”, Notre-Dame-du-Lac, Témiscouata
Project Manager: Hampton Timmy
Project Started: Jun 6, 2007
Total SCADA Sensors: 2170
Active SCADA Sensors: 1735
Manageable SCADA snsrs: 1771
Networking:
- The chassis of router Cisco 7606-S Chassis
- iBG910B Business Gateway, 8 x Ethernet ports, 2 x ISDN BRI ports, 2 x FXS ports, ADSL2 + Annex B WAN
- X900-48FE-80 48-Port Fast Ethernet L3 + Per-Flow QoS IPv4/IPv6 Switch.
One DC Power Supply Factory fitted. - Router 2821 w/AC PWR, 2GE, 4HWICs, 3PVDM, 1NME-X, 2AIM, IP BASE, 64F/256D
- Switchboard Cat4500 E-Series chassis 6-Slot Chassis, fan, no ps
- Modular router Cisco 3725 c 2-mja ports 10/100 with ON IP
Servers:
- 491335-421 Proliant DL380R06 L5520 (Rack2U XeonQC 2.26Ghz (8Mb)/2×2GbUD/P410i (ZM/RAID1+0/1/0)/noHDD (8 (16up)) SFF/noDVD/iLO2std/4xGigEth/1xRPS460)
- 538278-421 Proliant DL165R06 2427 Hot Plug SATA/SAS (Rack1U OptSC 2.2Ghz (6Mb)/2×2Gb (6400)/P212 (ZM/RAID1+0/1/0)/noLFF HDD (2/4up)/noDVD/2xGigEth)
- 490455-421 Proliant DL160R06 X5550 HP SATA/SAS HPM (Rack1U 2xXeonQC 2.66Ghz (8Mb)/6×2GbRD/P410wBBWC (256Mb/RAID5+0/5/1+0/1/0)/noLFF HDD (4)/noDVD/2xGigEth)
- 490427-421 Proliant DL160R06 E5504 NHP (Rack1U XeonQC 2.0Ghz (4Mb)/2×2GbUD/SATA RAID (1+0/1/0)/160GbSATA HDD (up to 4)/noDVD/2xGigEth)
- 491335-421 Proliant DL380R06 L5520 (Rack2U XeonQC 2.26Ghz (8Mb)/2×2GbUD/P410i (ZM/RAID1+0/1/0)/noHDD (8 (16up)) SFF/noDVD/iLO2std/4xGigEth/1xRPS460)
- AM438A Proliant DL785R6 8439SE (7U 4xOptSC 2.8Ghz (6Mb)/16×4Gb6400/no SFFHDD (8/16up)/RAID P400iwBBWC (512Mb)/2xGigEth MF/DVDcombo/iLO2std/6xRPS)
Power Systems:
- SYA16K16I APC Symmetra LX 16kVA/11.2kW Scalable to 16kVA/11.2kW N+1 Tower, 220/230/240V or 380/400/415V, input: 1PH/3PH, output: 1PH, Pre-Inst. Web/SNMP
- SUA3000XLI Smart-UPS XL 3000VA/2700W, 230V, Extended Runtime, Line-Interactive, user repl. batt., SmartSlot, USB, RS-232, PowerChute Tower/Rackmount (5U)
- SUA3000RMI2U Black Smart-UPS 3000VA/2700W, RackMount, 2U, Line-Interactive, USB and serial connectivity, user repl.batt, Automatic Voltage Regulation
- ACF400 Rack Air Removal Unit 100-240V 50/60HZ for NetShelter SX 600 mm Enclosure
Printing:
- Phaser 8560DX sngl.toner.printer f. А4 (512Mb,30чт/30ё-с.ё=Ё/ьшэ,600dpi,ѕыѕё°.2400dpi, a duplex
- Canon iR5055, 55ppm, A3, a paper
Desktop Software:
- The licence for use of the program of the control of the certificated version of OS Windows Server 2008 Datacenter (SrvDC08_Check)
- Package of certification for program complex Microsoft System Center Configuration Manager 2007
- Package of certification for 1 operated server device Data Protection Manager 2007 Enterprise Server Management
System Software:
- MAS2,5K MasterSCADA Arcive Server (MAS) – the allocated archival SCADA-server on 2500 arhiviruemyh parametres and 2500 external points of input-output.
- MAS-U MasterSCADA Arcive Server (MAS) – the allocated archival SCADA-server on unlimited quantity arhiviruemyh parametres and external points of input-output.
- Report-Inet-U The Generator of reports with possibility of viewing of reports in Internet clients (Internet Explorer) – unlimited quantity of simultaneously connected clients.
- MSRT1K-Net Network executive SCADA-system on 1000 external points of input-output
- MSRT-U-Red Redundant network executive SCADA-system on unlimited number of external points of input-output (on 2 computers).
Data Protection:
- B3PCIPAWSJ, PANDA Cloud Internet Protection – Advanced Web Security Module> 5001 licences (3 years), 657,3204
- B2GDICC? O, GateDefender Integra a full configuration 5 – 25 licences (2 years), 3046,1508
- B2UCOPCPE, Transition with Panda Cloud Email Protection on Panda Cloud Protection 101 – 250 licences (2 years), 1603,008