Branch of “Tanker – South”, Chemical Industry

Jun-22nd-2010

Client: Branch of “Tanker – South”, Saint-Gabriel, D’Autray
Project Manager: Calhoun Lillian
Project Started: Oct 22, 2009
Total SCADA Sensors: 2393
Active SCADA Sensors: 1669
Manageable SCADA snsrs: 1659

Networking:

  • iMG664A ADSL2/2 + Multiservice Gateway with Analog and Digital VoIP.

    1 x Annex A, ADSL2 +, 4 x 10/100TX, 2 x FXS, 1 x ISDN BRI
  • Switchboard Catalyst 2960 48 10/100 + 2 T/SFP LAN Base Image
  • Routing and ultrapure system code 135709
  • CV101 Media Blade 100TX to 100FX (ST), 2km Multimode
  • Switchboard Catalyst 3560 24 10/100/1000T + 4 SFP Standard Image
  • Router 2811 bundle, HWIC-1ADSL, SP Svcs, 64FL/256DR

Servers:

  • 466482-B21 HP BladeSystem cClass 8Gb Virtual Connect Fibre Channel Module (8 external SFP slots, incl 2×8Gb LC SW SFP) req. VC Eth Mod in Enclosure
  • 570103-421 Proliant DL385R06 2431 (Rack2U OptSC 2.4Ghz (6Mb)/2×4Gb/P410 (256Mb/RAID5+0/5/1+0/1/0)/noHDD (8 (16up)) SFF/noDVD/iLO2std/4xGigEth/1xRPS460)
  • 465475-421 Proliant DL120R05 E2160 NHP (Rack1U P1.8Ghz DC (1Mb)/1×1Gb/SATA RAID (1/0)/160GbSATA HDD (up to 2)/noCD.noFDD/GigEth)
  • AV340A Proliant DL160R06 E5504 NHP (Rack1U XeonQC 2.0Ghz (4Mb)/2×2GbUD/SATA RAID (1+0/1/0)/250GbSATA HDD (up to 4)/DVDRW/2xGigEth)
  • 470065-182 Proliant ML350T06 E5506 LFF (Tower XeonQC 2.13GHz (4Mb)/2×2GbRD/P410i (ZM/RAID1+0/1/0)/1×146Gb15kHDD (6LFF/8up)/DVDRW/iLO2std/2xGE/1xRPS460)

Power Systems:

  • SYA8K16I APC Symmetra LX 8kVA/5.6kW Scalable to 16kVA/11.2kW, N+1 Tower, 220/230/240V or 480/400/415V, in: 1PH/3PH, out: 1PH, Pre-Inst. Web/SNMP
  • SUVTP10KH2B2S APC Smart-UPS VT 10KVA/8kW 400V w/2 Batt Mod Exp to 2, Int Maint Bypass, Parallel Capable, w/Start-Up Servise
  • SYA16K16IXR APC Symmetra LX 16kVA/11.2kW Scalable to 16kVA/11.2kW N+1 Ext. Run Tower, 220/230/240V or 380/400/415V, input: 1PH/3PH, output: 1PH, Pre-Inst. Web/SNMP
  • SYARMXR9B9I APC Symmetra LX Extended Run Rack-mount w/9 SYBT5, 230V

Printing:

  • Canon iR6880C, 68ppm, A3, a paper
  • Phaser 5500B laz.printer (f. А3,50 str/mines, to 300К str/mes, 1200Х1200dpi, 500 MHz, 128Мб, AdobePS 3, PCL5e, PCL6,

Desktop Software:

  • Package of certification for 1 operated server device Center Operations Manager 2007 Standard Server Management
  • Package of the certificated terminal client access to Microsoft Windows Server 2008 c 1 automated workplaces
  • The licence for use of the program of the control of certificated version subd SQL Server 2008 Standard Edition (SQL08S_Check)
  • Acronis Backup and Recovery 10 Workstation incl. AAP el. Licence 500 – 999 Copies

System Software:

  • MSRT-X-SQL The Module of communication with a SQL-server (H – on demand of the client)
  • External HDA-clients (SCADA and MES systems, databases) can download all archives of the project. Corresponds to version OPC HDA 1.1
  • MSRT2,5K-Red Redundant network executive SCADA-system on 2500 external points of input-output (on 2 computers).
  • Report the Generator of reports

Data Protection:

  • B3PFLM, Panda Security for File Servers 101 – 1000 licences (3 years), 722,2197906
  • B3GDIWF? M, GateDefender Integra Web Filter Module 101 – 1000 licences (3 years), 241,153605
  • B3CEPG, Panda Cloud Email Protection 501 – 1000 licences (3 years), 2257,7632
  • B1GDINM? M, GateDefender Integra Network Module 101 – 1000 licences (1 year), 736,15311
Related